Tools & Safety Precautions

  • A Phillips head screwdriver
  • A 6mm electric drill
  • Plastic wall anchors
  • Torx head screws (M3x6)
  • A multimeter (recommended for verifying connections)

⚠ Important: Always disconnect power before working on electrical devices.

Step 1: Disconnect & Remove the Existing Device

  1. Turn off the power supply.
  2. Familiarize yourself with the five-pin cable system.
  3. Use a multimeter to verify wire connections.
  4. Carefully remove the existing device.
  5. Disconnect the wires one at a time to keep them accessible.
  6. Inspect the wires for damage—replace if needed.

Step 2: Install the Wall Mounting Box

  1. Align the rectangular hole of the wall mounting box with the hole in the wall.
  2. Mark four screw positions at the center of each mounting hole.
  3. Use a 6mm electric drill to make the holes.
  4. Insert plastic wall anchors into the holes.
  5. Secure the mounting box using four Phillips screws.
  6. Ensure the mounting box is level and properly aligned.
  7. Feed all the wires through the mounting box hole.

Step 3: Wire the CR Infinity Device

Connect the wires in the following order:

  • Zero wire
  • White wire for Wigan data (One)

Step 4: Mount the CR Infinity Device

  1. Align the CR Infinity unit with the mounting box.
  2. Hook the top of the device onto the mounting box.
  3. Gently lower the device into place.
  4. Secure it with two M3x6 Torx head screws at the bottom.
  5. Ensure the device is level and connections are secure.

Step 5: Power On & Test the Device

  1. Restore power to the device.
  2. Verify that the CR Infinity powers on correctly.
  3. Confirm that all connections are secure and the device is ready for operation.